Prenatal Prediction of Fetal Growth Restriction and Postnatal Outcomes by Ultrasound Assessment of Fetal Myocardial Performance Index and Blood Flow Spectrum

Evid Based Complement Alternat Med. 2022 May 5:2022:4234137. doi: 10.1155/2022/4234137. eCollection 2022.

Abstract

Objective: Fetal growth restriction (FGR) affects 5% to 10% of newborns and is a major determinant of perinatal morbidity and mortality. Myocardial performance index (MPI), also known as the Tei index, is a useful, noninvasive, and Doppler-derived myocardial performance tool for fetal cardiac function evaluation. The purpose of the study is to evaluate ultrasonic prediction on FGR and postnatal outcomes using MPI and blood flow spectrum.

Methods: This retrospective study included 240 pregnant women developing FGR and 240 healthy pregnant women. The blood flow spectrum of middle cerebral artery (MCA), umbilical artery (UA), and ductus venous including systolic to diastolic ratio (S/D), resistant index (RI), pulse index (PI), and peak ventricular systolic velocity/atrial contraction valley velocity (S/a) were examined using the GE Voluson E8 ultrasound system.

Results: The MPI, S/D, RI, PI of UA, and S/a were all higher but S/D, RI, and PI of MCA were lower in the FGR group than those in the control group (P < 0.001). The MPI, S/D, RI, PI of UA, S/D, RI, PI of MCA, and ductus venous S/a yielded AUC of 0.813, 0.835, 0.791, 0.804, 0.789, 0.796, 0.803, and 0.784 when they were used to predict the incidence of FGR. Of note, the pregnant women with poor pregnancy outcomes exhibited higher values of MPI, S/D, RI, PI of UA, and S/a with lower scores of 1 min Apgar concomitant with lower values regarding S/D, RI, and PI of MCA than those with favorable pregnancy outcomes (P < 0.001). The MPI (r = -0.623), S/D (r = -0.660), RI (r = -0.601), PI (r = -630) of UA, and S/a (r = -0.573) shared negative correlations with 1 min Apgar scores (P < 0.001). Of note, the S/D (r = 0.562), RI (r = 0.597), and PI (r = 0.619) of MCA were positively correlated with 1 min Apgar scores (P < 0.001). It was revealed that the MPI, S/D, RI, PI of UA, S/D, RI, PI of MCA, and ductus venous S/a yielded AUC of 0.806, 0.833, 0.774, 0.788, 0.807, 0.729, 0.748, and 0.770 when they were used to predict the incidence of poor pregnancy outcomes for pregnant women developing FGR.

Conclusion: Our study demonstrates good ultrasonic prediction on FGR and postnatal outcomes using MPI and blood flow spectrum.

Publication types

  • Retracted Publication